Materials characterization (SEM, TEM, XRD, XPS)

Which correctly describes the information depth of XPS (X-ray photoelectron spectroscopy) and the information it provides?

  1. AX-rays penetrate several micrometers into the specimen, so the average composition to a depth of several micrometers is obtained
  2. BThe information depth is a few nanometers, and chemical shifts of the peaks reveal the bonding state of elements (oxidation state and so on)
  3. CThe information depth is a few nanometers, but only the kinds of elements are revealed, not their bonding state
Show answer and explanation

Answer: B. The information depth is a few nanometers, and chemical shifts of the peaks reveal the bonding state of elements (oxidation state and so on)

In XPS the incident X-rays themselves penetrate several micrometers into the specimen, but the photoelectrons produced readily lose energy by inelastic scattering, and only those generated within a few nanometers of the surface escape with their original energy. XPS is therefore a technique that probes the topmost few nanometers. The binding energy of photoelectrons shifts slightly with the chemical state of the atom (chemical shift); for Si 2p, for example, SiO₂ is about 4 eV higher than elemental Si, so the presence of oxidation and the oxidation state can be distinguished. Depth distributions are investigated by measuring while sputtering with Ar ions or by varying the photoelectron take-off angle. Determining the average composition to a depth of several micrometers is the job of techniques such as EDS in the SEM.

Report an error

Practice this topic Back to topic

Related calculators

More Materials characterization (SEM, TEM, XRD, XPS) questions

  1. In XPS using Al Kα radiation (energy 1486.6 eV), the kinetic energy of Si 2p photoelectrons was measured as 1378.8 eV. If the spectrometer work function is 4.5 eV, which value is closest to the binding energy?
  2. In semiconductor failure analysis, which technique is best suited to measuring the depth profile of dopant concentration with sensitivity at the ppm to ppb level?
  3. When a polymer specimen is measured while being heated, which technique is suited to detecting the glass transition temperature Tg, and how does the transition appear?
  4. When calcium oxalate monohydrate (CaC₂O₄·H₂O, molar mass 146.1 g/mol) is heated in TGA, the water of crystallization is released first. Which value is closest to the percent mass loss in this first step? Take the molar mass of H₂O as 18.0 g/mol.
  5. In XRD with Cu Kα radiation (wavelength 0.15406 nm), which value is closest to the diffraction angle 2θ of the first-order peak from the Si (111) planes, with an interplanar spacing of 0.3135 nm?